Programming Model  
in the network or transceiver are HBERR, BABR, BABT, LC and RL. Interrupts resulting
from internal errors are HBERR and UN.
Some of the error interrupts are independently counted in the MIB block counters. Software
may choose to mask off these interrupts since these errors will be visible to network
management via the MIB counters.
• HBERR - IEEE_T_SQE
• BABR - RMON_R_OVERSIZE (good CRC), RMON_R_JAB (bad CRC)
• BABT - RMON_T_OVERSIZE (good CRC), RMON_T_JAB (bad CRC)
• LATE_COL - IEEE_T_LCOL
• COL_RETRY_LIM - IEEE_T_EXCOL
• XFIFO_UN - IEEE_T_MACERR
31
30
29
28
27
26
25
24
23
22
21
20
19
18
16
Field HBERR BABR BABT GRA TXF TXB RXF RXB MII EBERR LC
RL
UN
Reset
0000_0000_0000_0000
R/W
R/W
15
0
Field
Reset
0000_0000_0000_0000
R/W
R/W
Address
IPSBAR + 0x1004
Figure 17-4. Ethernet Interrupt Event
 
Register (EIR)
Table 17-12. EIR Field Descriptions 
Bits
Name
Description
31
HBERR
Heartbeat error. This interrupt indicates that HBC is set in the TCR 
register and that the COL input was not asserted within the 
Heartbeat window following a transmission.
30
BABR
Babbling receive error. This bit indicates a frame was received with 
length in excess of RCR[MAX_FL] bytes.
29
BABT
Babbling transmit error. This bit indicates that the transmitted 
frame length has exceeded RCR[MAX_FL] bytes. This condition is 
usually caused by a frame that is too long being placed into the 
transmit data buffer(s). Truncation does not occur.