Motorola MCF5281 사용자 설명서

다운로드
페이지 816
MOTOROLA
Chapter 29.  Debug Support  
29-25
Background Debug Mode (BDM)
Command/Result Formats:
Command Sequence:
Figure 29-22. 
READ
 Command Sequence
Operand Data
The only operand is the longword address of the requested location.
Result Data
Word results return 16 bits of data; longword results return 32. Bytes 
are returned in the LSB of a word result; the upper byte is undefined. 
0x0001 (S = 1) is returned if a bus error occurs.
15
12
11
8
7
4
3
0
Byte
 Command
0x1
0x9
0x0
0x0
A[31:16]
A[15:0]
 
Result
X
X
X
X
X
X
X
X
D[7:0]
Word
Command
0x1
0x9
0x4
0x0
A[31:16]
A[15:0]
Result
D[15:0]
Longword Command
0x1
0x9
0x8
0x0
A[31:16]
A[15:0]
Result
D[31:16]
D[15:0]
Figure 29-21. 
READ
 Command/Result Formats
XXX
’NOT READY’
READ (LONG)
???
MS ADDR
’NOT READY’
LS ADDR
’NOT READY’
NEXT CMD
’NOT READY’
NEXT CMD
LS RESULT
READ 
MEMORY
LOCATION
XXX
BERR
XXX
MS RESULT
XXX
’NOT READY’
READ (B/W)
???
MS ADDR
’NOT READY’
LS ADDR
’NOT READY’
NEXT CMD
’NOT READY’
READ 
MEMORY
LOCATION
XXX
BERR
NEXT CMD
RESULT