AC Electrical Characteristics
Electrical Characteristics
19-27
19.3.22  
Enter Self-Refresh Due to No Activity for 64 Clocks 
(Bit RM of DRAM Control Register = 1)
Figure 19-23 shows the timing diagram for enter self-refresh due to no activity. The signal values and units 
of measure for this figure are found in Table 19-16 on page 19-31. Detailed information about the 
operation of individual signals can be found in both Chapter 8, “LCD Controller,” and Chapter 7, “DRAM 
Controller.” 
Figure 19-23.   Enter Self-Refresh Due to No Activity Timing Diagram
SDCLK
RAS
SCKEN
CAS
A[16:1]/MD[15:0]
SDA10
CS
WE
Precharge
Command
Auto Refresh (SCKEN = 0)
Command