Lucent Technologies 6000 사용자 설명서

다운로드
페이지 586
5-8
   Preliminary January 4, 2001   
MAX 6000/3000 Network Configuration Guide
Configuring Frame Relay
Defining Frame Relay link operations
The following attributes can be used to define a frdlink pseudo-user profile:
Attribute
Value
Ascend-FR-Profile-
Name (180)
A Frame-Relay profile name (up to 15 characters), to be 
referenced in user profiles that make use of this datalink.
Ascend-FR-Nailed-Grp 
(158)
Group number assigned to nailed bandwidth in a line profile, such 
as a T1 or E1 profile. The default is 1. Make sure the Frame-Relay 
profile specifies the correct group number. If the channels are on 
nailed T1, make sure that the number of channels the MAX uses 
for the link matches the number of channels used by the device at 
the other end of the link, and that only one T1 profile specifies the 
Nailed-Group number to be used by the Frame Relay datalink.
Ascend-Call-Type (177)
Type of nailed connection: Nailed (1), Nailed/Mpp (2), or Perm/
Switched (3). Nailed is the default.
Ascend-Data-Svc (247)
Type of data service on the nailed link.Typically set to Nailed-64K 
for a Frame Relay datalink.
Ascend-FR-Link-Mgt 
(160)
The link management protocol. Settings are Ascend-FR-No-Link-
Mgt (0) (link management protocol is disabled), Ascend-FR-T1-
617D (1) (Annex D), and Ascend-FR-Q-933A (2)(CCITT Q.933 
Annex A). Ascend-FR-No-Link-Mgt is the default.
To ensure interoperability with equipment from different vendors, 
the same version of management protocol must be used at each 
end of the Frame Relay link.
Ascend-FR-Type (159)
Type of operations performed by the MAX on this interface. 
Settings are Ascend-FR-DTE (0), Ascend-FR-DCE (1), or 
Ascend-FR-NNI (2). Ascend-FR-DTE is the default. (For more 
information, see “Examples of a UNI-DTE link interface” on page 
5-9
, “Examples of a UNI-DCE link interface” on page 5-10, and 
“Examples of an NNI link interface” on page 5-12.)
Ascend-FR-N391 (161)
Number of T391 polling cycles between full Status Enquiry 
messages. The default is 6, which indicates that after 6 status 
requests spaced Ascend-FR-T391 seconds apart, the UNI-DTE 
device requests a Full status report. Does not apply when Ascend-
FR-Type is Ascend-FR-DCE.
Ascend-FR-DTE-N392 
(163)
Number of errors which, if occurring in the number of DTE 
monitored events specified by Ascend-FR-DTE-N393, causes the 
user-side to declare the network-side procedures inactive. The 
value should be less than that of Ascend-FR-DTE-N393l (which 
can be from 1 to 10). The default value is 3. Does not apply when 
Ascend-FR-Type is Ascend-FR-DCE.
Ascend-FR-DTE-N393 
(165)
DTE monitored event count (from 1 to 10). The default is 4. Does 
not apply when Ascend-FR-Type is Ascend-FR-DCE.