Lantronix 2100E 사용자 설명서

다운로드
페이지 93
7: Setup Mode: Channel Configuration 
WiBox® 2100E Device Server User Guide 
51 
Flow  
Flow control sets the local handshaking method for stopping serial input/output. The default 
setting is 00
Flow (00) ? _ 
Use the following table to select flow control options: 
Table 7-3. Flow Control Options 
Flow Control Option  
Hex  
No flow control  
00 
XON/XOFF flow control  
01 
Hardware handshake with RTS/CTS lines 
02 
XON/XOFF pass characters to host  
05 
Port Number 
The setting represents the source port number in TCP connections. It is the number that identifies 
the channel for remote initiating connections.  
Port No (10001) ? _ 
The default setting for Port 1 is 10001. The range is 1-65535, except for the following reserved 
port numbers:  
Table 7-4. Reserved Port Numbers 
 
 
 
 
 
 
 
Warning: We recommend that you not use the reserved port numbers for this setting as 
incorrect operation may result. 
Use Port 0 for the outgoing local port to change with each connection. The port range is 50,000 to 
59,999. Each subsequent connection increments the number by 1 (it wraps back around to 
50,000).  
Only use this automatic port increment feature to initiate a connection using TCP. Set the port to 
a non-zero value when the unit is in a passive mode or when using UDP instead of TCP.  
Port Numbers  
Reserved for  
1 – 1024 
Reserved (well known ports) 
9999  
Telnet setup  
14000-14009  
Reserved for Redirector 
30704 
Reserved (77F0h) 
30718 
Reserved (77FEh)