SM User Manual Issue 2
Page 12 of 34
INSTALLATION
The following steps are required to install the Canopy subscriber module.
•  Unpack the Canopy products
•  Configure the subscriber module for the Canopy network
•  Install the module
•  Align the module
UNPACK THE CANOPY PRODUCTS
Upon receipt, carefully inspect all shipping boxes for signs of damage.   If there is damage,
immediately notify the transportation company.
Unpack equipment, making sure that all ordered components have arrived.  It is recommended that
you save all the packaging materials.  They can be used for transportation of the equipment to and
from installation sites.
CONFIGURING THE SUBSCRIBER MODULE
In all cases, when a configuration parameter is modified, the change must be saved and
the module must be rebooted.
The subscriber module, from the factory, is configured to scan all available frequencies in its
specific frequency band.  An operator will need to verify the following information:
•  The operator may program a unique IP address into the subscriber module or can leave it
at its defaults.   The subscriber module is programmed to utilize the local IP address of
169.254.1.1.  When configured in this manner the IP address is not accessible from the far
side of a RF link to the module.  If the operator requires that the LAN IP of the subscriber
module be accessible from across the RF link then the public IP address feature is
recommended.   This feature will require that a routable IP address and appropriate subnet
mask and gateway be utilized.
•  The operator must configure the appropriate color code on the subscriber module so that it
can register with an access point module.  The color codes must match.
•  The operator can prevent unauthorized users from connecting to the subscriber module’s
web based interface by assigning a password.   There is no default password and
password protection is turned off from the factory.
Passwords can be from 1 to 16 characters.   Any  combination  of  characters  is  allowed,
except for these special characters: “ , . ‘ { } / \ ; : [ ] ( ) ` ~
NOTE:   If the operator forgets either the password or the IP address for the subscriber
module, a Canopy default plug can be used to regain access.  See 
Configuration
 section
for information on default plug.
There are two types of passwords that can be configured: display-only or full-access.  The
display-only password allows the operator to view the module’s current status.   The full-
access password allows the operator to view the module’s current status and change its
configuration.  By viewing the red lettering to the right of the entry fields, the operator can