Motorola 7000 사용자 설명서

다운로드
페이지 368
129
Link: 
Internal Servers
Your Gateway ships with an embedded Web ser ver and suppor t for a Telnet session, to allow ease of use 
for configuration and maintenance. The default por ts of 
80 for HTTP and 23 for Telnet may be reassigned. 
This is necessar y if a pinhole is created to suppor t applications using por t 80 or 23. 
 for more information on Pinhole configuration.
Web (HTTP) Server Port: To reassign the port number used to access the Motorola Netopia® embedded 
Web ser ver, change this value to a value greater than 1024. When you next access the embedded Motorola 
Netopia® Web ser ver, append the IP address with <por t number>, (e.g. Point your browser to 
http://
210.219.41.20:8080).
Telnet Server Port: To reassign the port number used to access your Motorola Netopia® embedded Telnet 
ser ver, change this value to a value greater than 1024. When you next access the Motorola Netopia® 
embedded Telnet ser ver, append the IP address with <por t number>, (e.g. 
telnet 210.219.41.20 2323).
You can also use the LAN-side address of the Gateway, 192.168.1.x:8100 to access the web ser ver and 
192.168.1.x:2323 to access the telnet ser ver. The value of 0 for an internal ser ver por t will disable that 
ser ver. You can disable Telnet or Web, but not both. If you disabled both por ts, you would not be able to 
reconfigure the unit without pressing the reset button.