Chapter 6.  Troubleshooting 
 
Mobile Broadband 11n Wireless Router MBR1210 User Manual 
Problems with Date and Time
The email screen displays the current date and time of day. The Mobile Broadband 11n 
Wireless Router uses the Network Time Protocol (NTP) to obtain the current time from one of 
several network time servers on the Internet. Each entry in the log is stamped with the date 
and time of day. Problems with the date and time function can include the following:
•     
Date shown is January 1, 2000. 
Cause: The router has not yet successfully reached a network time server. Check that 
your Internet access settings are configured correctly. If you have just completed 
configuring the router, wait at least 5 minutes, and check the date and time again.
•     
Time is off by one hour. 
Cause: The router does not automatically sense daylight savings time. On the E-mail 
screen, select or clear the Adjust for Daylight Savings Time check box.
Restoring the Default Configuration and Password
This section explains how to restore the factory default configuration settings, changing the 
router’s admin password to password and the IP address to 192.168.1.1. You can erase the 
current configuration and restore factory defaults in two ways:
•     
Use the Erase feature (see 
•     
Press the Restore Factory Settings button on the bottom of the router for 6 seconds. Use 
this method for cases when the administration password or IP address is not known.