Multi-Tech Systems GPRS (MTMMC-G) 사용자 설명서

다운로드
페이지 203
Chapter 13 – Specific AT Commands  
Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I) 
120 
 
Data Rate   +WDR 
Description: 
This command allows the data rate for bearer data to be configured for outgoing and incoming calls. 
Values:  
<out_coding_type>: Data Coding Type for Outgoing Calls. 
Data Coding 
Type 
Preferred 
Type 
Other Supported Types
Default Values 
FR 
 
Default incoming voice calls rate 
1 HR 
FR 
 
2 FR 
HR 
 
3 FR 
HR 
 
 
<in_coding_type>: Data Coding Type for Incoming Calls. 
Data Coding 
Type 
 Type 
Default Values
0 HR 
 
FR 
Default incoming data calls rate 
 
Command syntax:
 AT+WDR=  <out_coding_type>[,<in-coding_type>] 
AT+WDR= [<out_coding_type>],<in-coding_type> 
AT+WDR?   +WDR: <out_coding_type>[,<in-coding_type> 
Note: <out_coding_type> is related to outgoing calls, and <in_coding_type to incoming calls. 
Command   
Possible responses 
AT+WDR=? +WDR: 
(0-2),(0-2) 
Note: If Half Rate is available in both directions
 
AT+WDR=? +WDR: 
(0),(1) 
OK 
Note: If Half Rate is notavailable. 
AT+WDR=1 
Note: Configure data type FR, HR with HR 
preferred for outgoing calls 
(<in_coding_type> parameter is omitted) 
OK 
Note: Bearer is configured 
AT+WDR=1 
Note: Configure data type FRfor incoming 
calls (<out_coding_type> parameter is 
omitted) 
OK 
Note: Bearer is configured 
AT+WDR=3 
Note: Illegal value 
+CME ERROR: 3 
Note: Syntax error 
AT+WVR? 
Note: Ask for the current values 
+WVR: 1,1 
OK