User Manual                                                                               UMN:CLI 
SURPASS hiD 6615 S223/S323 R1.5 
A50010-Y3-C150-2-7619                                                                         81 
 
Fig. 5.2 
Port Mirroring 
 
To configure port mirroring, designate mirrored ports and monitor port. Then enable port 
mirroring function. Monitor port should be connected to the watch program installed PC. 
You can designate only one monitor port but many mirrored ports for one switch. 
Step 1
 
Activate the port mirroring, using the following command. 
Command Mode 
Description 
mirror enable 
Bridge 
Activates port mirroring. 
 
Step 2
 
Designate the monitor port, use the following command. 
Command Mode 
Description 
mirror monitor
 {PORTS I cpu
Bridge 
Designates the monitor port. 
 
Step 3
 
Designate the mirrored ports, use the following command. 
Command Mode 
Description 
mirror add
  PORTS  [ingress | 
egress
Bridge 
Designates the mirrored ports. 
ingress: ingress traffic 