Initial configuration
7
Initial configuration
Step one: Configure Ethernet Port A settings
The default setting for the ISDN gateway Ethernet ports is auto-sensing mode. If the 
switch ports to which you connect the ISDN gateway are not also set to auto-sensing 
mode, then you need to configure the ISDN gateway Ethernet ports to use the same 
speed and duplex mode.
To configure Ethernet Port A, log in to the Supervisor’s web interface and go to 
Hardware > Blades
. For more information about configuring the port, refer to the 
online help accessible from the Supervisor’s web interface.
Step two: Assign an IP address to the ISDN gateway
You can use the Supervisor’s web interface to configure the IP addresses of all blades 
installed in the MSE 8000. Note that all blades are supplied with DHCP enabled. You 
can either keep this setting or assign static IP addresses to a blade from the 
Supervisor’s web interface. To view or configure the IP address of the ISDN gateway, 
log in to the Supervisor and go to 
Hardware > Blades
. To access the web interface of 
the ISDN gateway, go to 
Hardware > Blades
 and click the IP address of that blade.
Only connect to Ethernet Port A. Ethernet Port B is reserved for future 
expansion; do not connect anything to Ethernet Port B.
Both ends of the Ethernet connection must be configured in the same 
way. For example, either configure both ends of the link to be auto-
sensing or configure both ends to operate at the same speed and duplex.
To establish a 1000Mbps connection, both ends of the link must be 
configured as auto-sensing.