Proxim AP-2000 사용자 설명서

다운로드
페이지 244
156
Using the Command Line Interface (CLI)
Set Hardware Configuration Reset Parameters
The Hardware Configuration Reset commands allows you to enable or disable the hardware reset functionality and to 
change the password to be used for configuration reset during boot up.
To disable hardware configuration reset, enter: 
[Device-Name]>set hwconfigresetstatus disable
To enable hardware configuration reset, enter: 
[Device-Name]>set hwconfigresetstatus enable
To define the Configuration Reset Password to be used for configuration reset during boot up, enter the following 
command
[Device-Name]>set configresetpasswd <password>]
It is important to safely store the configuration reset password. If a user forgets the configuration reset password, the 
user will be unable to reset the AP to factory default configuration if the AP becomes inaccessible and the hardware 
configuration reset functionality is disable.
Set VLAN/SSID Parameters
Enable VLAN Management
[Device-Name]>set vlanstatus enable 
[Device-Name]>set vlanmgmtid <-1-4094>
[Device-Name]>show wifssidtbl (to review your settings)
[Device-Name]>reboot 0
Disable VLAN Management
[Device-Name]>set vlanstatus disable or 2
[Device-Name]>set vlanmgmtid 0
[Device-Name]>reboot 0
CLI Monitoring Parameters
Using the show command with the following table parameters will display operating statistics for the AP (these are the 
same statistics that are described in 
 for the HTTP Web interface).
staticmp: Displays the ICMP Statistics.
statarptbl: Displays the IP ARP Table Statistics.
statbridgetbl: Displays the Learn Table.
statiapp: Displays the IAPP Statistics.
statradius: Displays the RADIUS Authentication Statistics.
statif: Displays information and statistics about the Ethernet and wireless interfaces.
stat802.11: Displays additional statistics for the wireless interfaces.
statethernet: Displays additional statistics for the Ethernet interface.
statmss: Displays station statistics and Wireless Distribution System links.
Parameter Tables
Objects contain groups that contain both parameters and parameter tables. Use the following Tables to configure the 
Access Point. Columns used on the tables include:
— Name - Parameter, Group, or Table Name
— Type - Data type
— Values - Value range, and default value, if any
— Access = access type, R = Read Only (show), RW = Read-Write (can be “set”), W = Write Only
— CLI Parameter - Parameter name as used in the Access Point