Chapter 2 - Hardware Installation
2-28
Mounting the MGC+50 on a Rack
The MGC+50 can be mounted in a 19” rack using two mounting plates (Kit 
2012A). The side plates are usually mounted when shipped, but if not, follow 
the directions below to install the mounted plates on the MGC+50 and then 
mount the MGC+50 on the 19” rack.
To install and mount the MGC+50:
1.
Make sure that the MGC+50 power is turned OFF and it is disconnected 
from the AC power.
2.
Remove the five nylon plug hole covers from the MGC+50 protective 
side covers (using a slotted screwdriver).
3.
Using an Allen wrench (M4), remove the five screws from the MGC+50 
side covers.
4.
Remove the MGC+50 side covers from both sides.
5.
To remove the plate from both MGC+50 sides, the side screws have to be 
removed. To remove the screws from the left side of the MGC+, the 
Control Board, Server panel, Functional modules and power supply must 
be removed first. These procedures are described in Chapter 5 of this 
manual. For detailed procedures, see Chapter  5, “Replacing the Main 
Control Module” on page 5-17. Fo
r instructions on how to remove the 
power supply, see Chapter  5, “Replacing the Power Supply Module on 
the MGC+50” on page 5-11.
front
remove
side cover