RAD Data comm ASMi-52 사용자 설명서

다운로드
페이지 186
Installation and Operation Manual 
Chapter 6  Troubleshooting and Diagnostics 
ASMi-52 Ver. 2.5 
Handling Alarms 
6-13 
Table 6-3.  ASMi-52 Alarms and Warnings (Cont.) 
Number Terminal 
Message 
Port 
Description 
Severity 
32 
E1 EXCESIVE ERR 
RATIO 
T1 EXCESIVE ERR 
RATIO 
DTE 
The bit error rate of the link exceeds 10
-3
 
Major 
33 
E1 AIS OCCURED 
T1 AIS OCCURED 
DTE 
AIS is detected at the E1 or T1 port 
Major 
34 
E1 AIS AND SYNC 
LOSS 
T1 AIS AND SYNC 
LOSS 
DTE 
AIS and loss of frame alignment are detected at 
the E1 or T1 port 
Major 
35 E1 
SYNC 
LOSS 
T1 SYNC LOSS 
DTE 
E1 or T1 loss of frame synchronization occurred 
Major 
36 
E1 CRC MF EXC 
DTE 
CRC errors detected in the frame synchronization 
signal exceeded the threshold 
Minor 
37 
E1 REMOTE SYNC 
LOSS 
T1 REMOTE SYNC 
LOSS 
DTE 
Remote loss of frame synchronization occurred  
Major 
38 
E1 MF SYNC LOSS 
DTE 
Local loss of frame synchronization 
Major 
39 
E1 MF REMOTE SYNC 
LOSS 
DTE 
Remote loss of frame synchronization 
Major 
40 
E1 TS NOT X128 
T1 TS NOT X128 
DTE 
Number of timeslots assigned for the ASMi-52 
unit with 4-wire line interface is not n×128 
Major 
41 
E1 TS NOT COMP 
T1 TS NOT COMP 
DTE 
Number of timeslots assigned for the local unit 
does not match the number of timeslots assigned 
for the remote unit. 
Major 
42 WIRE 
MODE 
NOT 
COMP 
SHDSL 
Mismatch between line interface types (2/4-wire) 
between local and remote units 
Major 
43 
SPAN IS NOT FULL 
SHDSL 
The distance between adjacent repeaters is too 
long. You can identify the problematic segment 
by checking the Port Status screen. In the 
Number of Repeaters line, it displays the last 
repeater identified by ASMi-52. This means that 
the distance between the last detected repeater 
and the next repeater exceeds its maximum 
range. 
Major 
44 LOOP 
ATTN. 
OVER 
NETWORK SIDE 
SHDSL 
Loop attenuation at the network side of the 
repeater has exceeded the alarm threshold 
Major