RAD Data comm ASMi-52 사용자 설명서

다운로드
페이지 186
Installation and Operation Manual 
Chapter 6  Troubleshooting and Diagnostics 
ASMi-52 Ver. 2.5 
Testing ASMi-52 
6-21 
 
To run the local loopback: 
1.  From the Main menu, select Diagnostics
The Diagnostics menu is displayed (see 
Figure 6-22
). 
2.  From the Diagnostics menu, select: 
 
Local Test
 to run the LLB on the local ASMi-52 
 
Remote Test 
to run the LLB on the remote ASMi-52. 
The Local/Remote Test menu appears (see 
Figure 6-23
). 
3. Select LLB
The LLB value in parenthesis changes to ON. Also, an additional 
parameter, Loop Timeout, is displayed for the local ASMi-52. 
4. Select Loop Timeout, if you want to set loopback timeout (in minutes). 
The Loop Timeout value changes. 
 
Avoid setting timeout to 0 as local control is lost during LLB. 0=Forever 
 
5.  Once you selected the loopback timeout, select Save to activate the LLB. 
The LLB is initiated. The TST indicator lights up and the ASMi-52 units lose 
synchronization. 
ASMi-52 
Diagnostics 
5. Local Test 
6. Remote Test 
7. Repeater Test 
 
ESC-previous menu ; !–main menu ; &–exit terminal  
Figure 6-22.  Diagnostics Menu 
ASMi-52 
Local Test or Remote Test 
LLB from DTE: OFF 
RLB from DTE: OFF 
1. Bert 
 
2. LLB (ON) 
3. Loop Timeout (min)(0-4095)     ...(5) 
4. LEDs test 
5. Clear all 
6. Save 
 
ESC-previous menu ; !–main menu ; &–exit; @-scroll 
 
Figure 6-23.  Local/Remote Test Menu 
Note