Erasing IR-IP Software 
B-29 
Erasing Application Software 
 
To erase the application software: 
1. Turn ASMi-52 off. 
2.  Set all the four sections of IR-IP DIP switch to ON. 
3.  Turn ASMi-52 on and monitor the ERR and LINK indicators: they must blink 
alternately. 
4.  While ERR and LINK are blinking (within 15 seconds), set sections 3 and 4 of 
the DIP switch to OFF. 
The IP router application software is erased. During the process of erasing, 
the ERR indicator turns on and lights steadily. 
 
If you do not set sections 3 and 4 to OFF within 15 seconds of power-up, IR-IP 
ignores the setting of all the four sections to ON and starts normal operation. In this 
case, it is recommended to turn ASMi-52 off and then back on. 
Alternately, to abort the whole operation, turn ASMi-52 off, return all the four 
switches to the desired positions, and then turn ASMi-52 on again. 
 
5.  Turn ASMi-52 off, and then return all the four sections of the DIP switch to the 
desired positions. 
Downloading New Software 
After erasing the application software, you can download new software from any 
computer that can serve as a TFTP client. 
To enable the downloading, IR-IP automatically activates its TFTP server 
application with the following factory-default IP parameters: 
•  IP address: 
192.168.205.1 
•  Subnet mask: 
255.255.255.252. 
Connect the computer serving as a TFTP client to the IR-IP 10BASE-T connector in 
the way as a Telnet host used for preliminary configuration (see the 
Performing 
Preliminary Configuration
 section). The computer IP parameters must be 
configured as follows: 
•  IP address 
192.168.205.2 
•  Subnet mask 
255.255.255.252 
•  Default gateway 
192.168.205.1 
 
To download new software: 
1.  If necessary, turn ASMi-52 off. 
2.  Set all the four sections of the IR-IP DIP switch to OFF. 
3. Turn ASMi-52 on. 
4.  Connect the computer to the IP router LAN interface (for the 10BaseT version, 
verify that the LINK indicator lights steadily) and configure its IP parameters as 
explained above. 