1. Introduction
RuggedCom® RuggedMAX WiN7000
12
Installation Guide Rev1
1.3.8. Antenna Grounding Requirements
The  antenna  installation  must  be  as  per  Article  810  of  the  NEC.  Of  particular  note  is  the
requirement  that  the  grounding  conductor  not  be  less  than  10  AWG  (Cu).  The  scheme  should
be either in accordance with UL 96 and 96A Lightning Protection Components and Installation
Requirements for Lightning Protection Systems, or tested in accordance with UL 50 and UL 497.
1.3.9. Outdoor Grounding System
Verify that the base station is grounded.
The  system  must  be  properly  grounded  to  protect  against  power  surges  and
accumulated static electricity. It is the installer’s responsibility to install this device in
accordance with the local electrical codes.
1.3.10. User ports and power supply
If the length of outdoor exposed communication lines is greater than 40 m (140 feet), these lines
must be treated as TNV-1 circuits. The installer must ensure that the power supply and network
ports are designed for full compliance with the TNV-1 telecommunication network.
1.3.11. Safety Hazards
Installing the WiN7000 can pose a serious hazard. Be sure to take precautions to avoid
the following:
• Exposure to high voltage lines during installation
• Falling when working at heights or with ladders
• Injuries from dropping tools
• Contact with AC wiring (power system connection)
To reduce the risk of fire, use only 26AWG or larger telecommunication line cord.