RAD Data comm E1/T1 사용자 설명서

다운로드
페이지 224
FCD-IPM Installation and Operation Manual 
Chapter 1  Introduction 
 
Technical Specifications 
1-13 
 
 
FXO
: Loop start, WINK start (reverse polarity) 
for connection to a 2-wire telephone 
exchange subscriber line 
Nominal level: 0 dBm 
Nominal impedance: 600Ω 
Return loss (ERL): Better than 18 dB 
Frequency response: (Ref: 1020 Hz) 
•  ±0.5 dB, 300 to 3000 Hz 
•  ±1.1 dB, 250 to 3400 Hz 
Signal to total distortion, G.712, G.713 
method 2: 
•  0 to –30 dBm0, better than 33 dB 
•  +3 to –45 dBm0, better than 22 dB 
Idle channel noise: Better than –70 dBm0 
(+20 dBrnc) 
Transformer isolation: 1500 VRMS 
 
Diagnostics 
Remote analog loopback towards the remote 
side, activated from local side 
1kHz tone injection towards analog side 
Activity indicators 
ISDN 
Interfaces 
ISDN BRI, “S” and “U” 
 
Compliance 
ETS 300012 
I.430 
NT1 
5ESS 
DMS-100 
NI1 
WAN Protocols 
Types 
Frame Relay – RFC 1490 
PPP and MLPPP 
Routing 
Types 
STATIC 
RIP-1 
RIP-2 
RIP/SAP 
OSPF