Avaya CMC1 사용자 설명서

다운로드
페이지 370
Upgrading R9csi/R10csi/Communication Manager 1.x/2.x to Avaya Communication Manager 2.2 on an
220 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
Check link status
To check link status:
1. Enter display communication-interface links and press RETURN.
2. Note all administered links.
3. Type status link number and press RETURN for each administered link.
Check the following fields for the values listed:
Link Status
 = connected
Service State
 = in service
Note:
Note:
For Release 7 and later, the only way to determine if an ISDN-PRI D-Channel is 
up is to type status signaling group and press RETURN.
4. If any of the links are not up, take the necessary corrective action to restore the link before 
continuing with the upgrade.
Save translations
To save translations:
1. Type save translation and press RETURN to write all translations from memory to the 
translation flashcard (about 10 minutes).
2. Ensure that the save translation command was successful (error code must be zero). If the 
value is anything else, the translations were not copied to the flashcard. If the translations 
are corrupted, the following error message appears when logging in:
!
WARNING:
WARNING:
Translation corruption detected; call an Avaya distributor immediately.
Note:
Note:
The save translation command does not run if the translations are corrupt or do 
not match (duplicated systems only).