Avaya CMC1 사용자 설명서

다운로드
페이지 370
Adding or Removing Hardware
296 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
Installing a J58890CG Power
Distribution Unit
Mounting without a backing plate
Note:
Note:
Note: the J58890CG Power Distribution Unit should be installed to the right of the 
SCC Cabinet Stack, and mounted approximately 12 inches (30.5 cm) off the floor. 
To install the J58890CG Power Distribution Unit on a wall without a plywood backing plate, use 
the following procedure:
1. Hold the unit at the desired location (see Note) and mark the 4 (four) holes (slots and 
keyholes) centers with a pencil.
2. Use a level to make sure the unit is straight, set the unit aside and install 4 (four) ZINC 
drywall “screw in” anchors rated for 50 LBS each minimum.
3. Install the TOP 2 (two) screws supplied with the zinc anchors.
4. Install the power distribution unit onto the top screws.
5. Install the bottom screws through the slots in the power distribution housing.
Mounting with a backing plate
Note:
Note:
Note: the J58890CG Power Distribution Unit should be installed to the right of the 
SCC Cabinet Stack, and mounted approximately 12 inches (30.5 cm) off the floor. 
To install the J58890CG Power Distribution Unit on a wall with a plywood backing plate, use the 
following procedure:
1. Hold the unit at the desired location (see Note) and mark the 4 (four) holes (slots and 
keyholes) centers with a pencil.
2. Use a level to make sure the unit is straight, set the unit aside and install 2 (two) #12 pan 
head phillips wood screws (rated for 50 LBS each minimum) in the top position.
3. Install the power distribution unit onto the top screws.
4.  Install the bottom screws through the slots in the power distribution housing.