Install paging and announcement equipment
Issue 10 June 2005
353
 
Loudspeaker paging with universal coupler
An information outlet provides access to loudspeaker paging. The system side of the main 
distribution frame connects to a 909A/B universal coupler. Make provisions for the DC power 
that the 909A/B universal coupler requires, such as a 1151A, 1151A2, or other approved 
-48VDC power supply.
Six leads (T, R, SZ, SZ1, S, and S1) connect the adapter to an auxiliary trunk circuit pack 
located in a port carrier.
1. Determine port assignment of paging zone(s) from loudspeaker Paging form.
2. Identify carrier slot and label both ends of an A25D (male to male) cable.
3. Connect a cable from the 909A/B to the system side of the main distribution frame. A wiring 
block must be locally engineered.
4.
on page 343 provides details of the connections between 
the 909A/B universal coupler and the wiring blocks.
!
CAUTION:
CAUTION:
Damage to the 909A/B may occur if the cable is plugged into J3 before all 
cross-connects are completed. 
5. On the 909A/B universal coupler:
Connect seizure control voltage of from -9 to -70 volts to the PG2/BZ2 connection (pin 2 
of J1). Switching voltage to the PG2/BZ2 connection can be from the 909’s -48-volt 
supply.
Connect a -48 VDC power source to the -48 and GRD terminals on the 909A/B.
6. Install patch cord/jumper wires at the main distribution frame.
7. Connect a 2-pair line cord (modular plug at one end) from the information outlet to the 
loudspeaker system.
8. Install loudspeaker equipment according to the manufacturer’s instructions.
9. Connect an approved -48 VDC power source to the -48 and GRD terminals (pins 5 and 2, 
respectively, of J3).
10. Administer the switch for the new equipment.
Note:
Note:
For additional installation information, refer to 909A/909B Universal Coupler 
Installation Instructions
, which is normally shipped with the 909A/909B Universal 
Coupler.