Cabletron Systems NBR-420 사용자 설명서

다운로드
페이지 73
EPIM-F3
NBR-SERIES Installation Guide
Page B-3
B.4 EPIM-F3
The EPIM-F3 shown in Figure B-3 supports Single Mode Fiber Optic 
cabling. It has an internal Cabletron Systems FOT-F Fiber Optic 
Transceiver and is equipped with ST Connectors. Specifications for the 
EPIM-F3 are listed below.
Figure B-3
EPIM-F3
Transmitter Power decreases as temperatures rise and increases as 
temperatures fall. Use the Output Power Coefficient to calculate increased 
or decreased power output for the operating environment. For example, 
the typical power output at 25
°
C is -16.4 dBm. For a 4
°
C temperature 
increase, multiply the typical coefficient (-0.15 dBm) by four and add the 
result to typical output power (4 x -0.15 dBm + -16.4 = -17.0).
1092_23