Bosch D6100 사용자 설명서
Conettix D6600/D6100 | Computer Interface Manual | Appendix I:
D6600 SafeCom Messages
.
Bosch Security Systems, Inc. | 1/07 | 4998122703-01
161
Table 112: D6600 SafeCom Messages - Line Card or Account Signals (continued)
# Event
Device/
Mode
Mode
Display Notes
on
Auto
Output
6500
SIA
SIA
1
hprrl0aaa03200304t
<header>[#0aaa|03200304]
27.
Silent/Medical Panic
Printer
2
dd/dd tt:tt Sxx aaa>SILENT/MEDICAL
PANIC
PANIC
Only valid for
SC5000
SC5000
6500
SIA
SIA
1
hprrl0aaa03200305t
<header>[#0aaa|03200305]
28. Operator
Evacuation
Bell
Printer
2
dd/dd tt:tt Sxx aaa>OPERATOR EVACUATION
Only valid for
SC5000
SC5000
6500
SIA
SIA
1
hprrl0aaa0320011it
<header>[#0aaa|0320011i]
29.
Input Normal
Printer
2
dd/dd tt:tt Sxx aaa normal: input i
6500
SIA
SIA
1
hprrl0aaa0320021it
<header>[#0aaa|0320021i]
30. Input
Open
Printer
2
dd/dd tt:tt Sxx aaa>OPENED: input i
6500
SIA
SIA
1
hprrl0aaa0320031it
<header>[#0aaa|0320031i]
31.
Input Short
Printer
2
dd/dd tt:tt Sxx aaa>SHORTED: input i
6500
SIA
SIA
1
hprrl0aaa0320041it
<header>[#0aaa|0320041i]
32. Input
Bypass
Printer
2
dd/dd tt:tt Sxx aaa bypass: input i
6500
SIA
SIA
1
hprrl0aaa0320051it
<header>[#0aaa|0320051i]
33.
Input Unbypass
Printer
2
dd/dd tt:tt Sxx aaa unbypass: input i
6500
SIA
SIA
1
hprrl0aaa0320011zt
<header>[#0aaa|0320011z]
34. Zone
Restore
Printer
2
dd/dd tt:tt Sxx aaa restore: zone z
Only valid for
SC5000
SC5000
6500
SIA
SIA
1
hprrl0aaa0320021zt
<header>[#0aaa|0320021z]
35.
Zone Trouble
Printer
2
dd/dd tt:tt Sxx aaa>TROUBLE: zone z
Only valid for
SC5000
SC5000
6500
SIA
SIA
1
hprrl0aaa0320031zt
<header>[#0aaa|0320031z]
36. Fire
Alarm
Printer
2
dd/dd tt:tt Sxx aaa>FIRE: zone z
Only valid for
SC5000,
depending on the
zone type
SC5000,
depending on the
zone type
6500
SIA
SIA
1
hprrl0aaa0320031zt
<header>[#0aaa|0320031z]
37.
Silent Alarm
Printer
2
dd/dd tt:tt Sxx aaa>SILENT: zone z
Only valid for
SC5000,
depending on the
zone type
SC5000,
depending on the
zone type
6500
SIA
SIA
1
hprrl0aaa0320031zt
<header>[#0aaa|0320031z]
38. Burglary
Alarm
Printer
2
dd/dd tt:tt Sxx aaa>BURGLARY: zone z
Only valid for
SC5000,
depending on the
zone type
SC5000,
depending on the
zone type
6500
SIA
SIA
1
hprrl0aaa0320041zt
<header>[#0aaa|0320041z]
39.
Zone Bypass
Printer
2
dd/dd tt:tt Sxx aaa BYPASS: zone z
Only valid for
SC5000
SC5000
6500
SIA
SIA
1
hprrl0aaa0320051zt
<header>[#0aaa|0320051z]
40. Zone
Unbypass
Printer
2
dd/dd tt:tt Sxx aaa unbypass: zone z
Only valid for
SC5000
SC5000
1 - Refer to Table 114 Explanation of Automation Output Items (within Message Body only) on page 164.