Siemens SM2 monitoring system 사용자 설명서

다운로드
페이지 500
U3585-J-Z125-8-76
219
SM2 reports
BCAM CONNECTION report
Monitoring information
SET
Name of the connection set
# CONNECTIONS
Number of (active) connections in the connection set.
The computation includes only those connections that were active
both at the current monitoring time and at the end of the preceding
monitoring cycle.
IN/OUT
Data sent and received
TSDU
Number of TSDUs per second
TSDUs (Transport Data Service Units) correspond to application
jobs on BCAM.
DATA
Average volume of data in KB per TSDU
BUFFER
Amount of cache space occupied by unretrieved messages in KB
and as a percentage of the maximum buffer size.
This value describes the status at the end of the monitoring cycle,
and not the mean value over the entire monitoring cycle.
PWIN
Number of packets without user data (Packet WINdow) per second
PDATA
Number of packets with user data (Packet DATA) per second
SCOM
Number of send jobs per second in the event of a resource
bottleneck (Send Call Over Maximum)
ZWR
Number of packets with Zero Window Information per second, i.e.
where the partner application does not allow the sending of any
further data
INWAIT TIME
Time between the display of a message and the retrieval of that
message from the application
REACT TIME
Time between an application’s send call and the receive call which
immediately precedes it
INPROC TIME
Time between the arrival of a message at BCAM and the retrieval of
that message by the application
OUTPROC TIME
Time between a send call and the transfer of the last byte of a
message to the network
BUCKET
Limit values in milliseconds of the ranges within which the
monitored data is arranged by order of magnitude.
> indicates overflow values.
COUNT
Number of messages sent/received in the individual ranges