Philips SPX 15-35 사용자 설명서

다운로드
페이지 14
SPX Operation Manual 
 
11 
 
 
 
 
 
Version 1.1: 2010         © 2010 Philips Selecon All Rights Reserved
 
 
 
Insulation Resistance Testing for class 2 appliance of the SPX is to be performed by a suitably qualified or 
competent person (as defined by the standard or local laws) using an ohmmeter (i.e. Megger) or portable 
appliance tester (PAT Machine) by applying a nominal voltage to the live conductors (active and neutral pins 
on plug) of the SPX, and placing a 0 volt reference probe on the external metal parts of the SPX;
 
 
Lamp module must be in place during tests       
  
Test active & neutral to accessible earthed parts 
 
 
Insulation resistance limits 
Equipment 
Insulation Test 
Minimum insulation 
resistance M
Ω 
Class II 
With live and neutral conductors electrically 
connected measure between live parts and any 
accessible metal parts. 
 
In accordance with AS/NZS 3760 
Cleaning the Reflector 
 
First remove the lamp module and lamp 
– refer page 4. 
Remove  the  lens  barrel  and  shutter  assembly  by  undoing  the  shutter 
and  reflector  assembly  rotation  knob,  and  removing  the  shutter/lens 
assembly. 
A soft cloth soaked in a mild detergent solution or alcohol can be used 
to remove dirt from the mirror. 
 
 
 
 
 
 