SPX Operation Manual 
 
 
 
 
 
 
Version 1.1: 2010         © 2010 Philips Selecon All Rights Reserved
 
 
Safety Warnings 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Not for residential use. 
 
 
CAUTION: Hot Surfaces, Avoid contact by persons or materials. 
The SPX has some hot surfaces. Be careful to avoid burns. Take care with the lamphouse 
and heat-sink. We suggest the use of leather gloves when focusing these luminaires. 
 
SAFETY 
– Double Insulated  
The SPX range is a Class 2 appliance that is double insulated for increased safety and 
lower maintenance. Earth continuity testing is not needed. Refer to page 11 for testing 
procedure. 
 
SAFETY - Mains Power Isolation 
The SPX range is fitted with a micro-switch that automatically disconnects the mains 
power when the lamp holder is removed. However, it is also recommended that the 
luminaire should always be electrically isolated from mains power before re-lamping, 
cleaning or servicing. 
 
 
CAUTION: Risk of fire - use with maximum 800W lamp. 
 
 
CAUTION: These luminaires are not suitable for mounting on a normally flammable 
surface. 
 
These luminaires are not suitable for outdoor use. They are rated at IP00. 
 
 
The luminaire should be at least 1.2 metres/4 ft away from the nearest object it is lighting. 
 
The SPX range can be operated only through a range of angles 90
 either side of 
horizontal.
Operating your Luminaire for the First Time 
 
Familiarise  yourself with the way the shutter and reflector assembly can be rotated by  loosening the rotating 
clamp (drawing page 9), and turning the assembly. Note how  the colour frame is locked into the front of the 
lens tube with the front accessory cover. 
 
The SPX provides for mounting 2 pattern holders. Practice inserting them into both the front and rear position 
as it is easier to familiarise yourself before rigging the luminaire. 
 
The SPX has a shutter lock. Make sure this is in the unlocked position. Refer P.7 
 
Lamping Procedure  
Remove  the  lamp  module  by  loosening  the  2 
locking thumbscrews on the rear. Align the pins 
of the new lamp to the holes in the lamp socket 
and  push  the  lamp  firmly  home.  Do  not  touch 
the  quartz  envelope  of  the  lamp  with  your 
fingers.  Replace  the  lamp  module  and  tighten 
the locking thumbscrews. Reconnect the mains 
power. Always take great care when making 
adjustments  to  the  lamp,  as  its  filament  is 
fragile.  N.B.  The  mains  power  supply  is 
automatically 
disconnected 
by 
microswitch 
as 