Runco CL-810 사용자 설명서

다운로드
페이지 58
13
Runco CL-810 Owner’s Operating Manual
1.  LAMP LED
 
Indicates the status of the lamp
 
- Red when the lamp has exceeded
 
its usage life or developed a  
 
 
problem. Please contact your Runco  
 
Dealer for assistance.
 
- Flashing Red when the fans are
 
not working or the lamp cover is    
 
open. Please contact your Runco    
 
Dealer for assistance.
2.  POWER LED
 
Indicates the status of the power
 
- Orange when the AC power cord   
 
is plugged into a wall outlet (standby  
 
mode). Once in standby mode, you  
 
can turn on the projector by  
 
pressing the ON button on the  
 
 
remote control.
 
- Green when the power is turned    
 
on (operational mode).
 
- Flashing Orange for the first 45    
 
seconds after power-up indicating   
 
that the lamp is warming up.
 
- Flashing Green for 110 seconds
 
after the projector was powered off  
 
indicating that the lamp is cooling  
 
down.
3.  TEMP LED
 
Indicates the status of the fans and 
 
internal temperature
 
- Red when the internal temperature  
 
is too high. Please contact your  
 
 
Runco Dealer for assistance.
 
- Flashing Red when the fans are
 
not working or the lamp cover is
 
open. Please contact your Runco    
 
Dealer for assistance.
4.  TOP IR SENSOR
Controls and Functions
Control Panel