Regarding the indicator lamps
Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator 
have the meanings as described in the table below. Please respond in accordance with the 
instructions within the table. If the same indication is displayed after the treatment, or if an 
indication other than the following is displayed, please contact your dealer or service com-
pany.
POWER
indicator
LAMP
indicator
TEMP
indicator
Description
Lighting In 
Orange
Turned off
Turned off
The projector is in a standby state.
Please refer to the section “Power On/Off”.
Blinking In 
Green
Turned off
Turned off
The projector is warming up.
Please wait.
Lighting In 
Green
Turned off
Turned off
The projector is in an on state.
Ordinary operations may be performed.
Blinking In 
Orange
Turned off
Turned off
The projector is cooling down.
Please wait.
Blinking In 
Red
(discre-
tionary)
(discre-
tionary)
The projector is cooling down. A certain error has 
been detected.
Please wait until the POWER indicator finishes blink, and 
then perform the proper response measure using the item 
descriptions below as reference.
Blinking In 
Red or 
Lighting In 
Red
Lighting In 
Red
Turned off
The lamp does not light, and there is a possibility that 
interior portion has become heated.
Please turn the power off, and allow the unit to cool down 
at least 20 minutes. After the projector has sufficiently 
cooled down, please make confirmation of the following 
items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35
o
C?
If the same indication is displayed after the treatment, 
please change the lamp by referring to the section 
“Lamp”.
Blinking In 
Red or 
Lighting In 
Red
Turned off
Blinking In 
Red
The cooling fan is not operating.
Please turn the power off, and allow the unit to cool down 
at least 20 minutes. After the projector has sufficiently 
cooled down, please make confirmation that no foreign 
matter has become caught in the fan, etc. and then turn 
the power on again.
If the same indication is displayed after the treatment, 
please contact your dealer or service company.