Related messages (continued) 
Message Description 
CHECK THE AIR FLOW 
The internal portion temperature is rising. 
Please turn the power OFF, and allow the unit to cool 
down at least 20 minutes. After having confirmed the 
following items, please turn the power ON again. 
  • Is there blockage of the air passage aperture? 
  • Is the air filter dirty? 
  • Does the peripheral temperature exceed 35°C? 
  • If the same indication is displayed after the treatment, 
please set the HIGH at the FAN SPEED of the item 
SERVICE of the OPTION menu. 
CLEAN THE AIR FILTER 
POWER OFF FIRST,   
THEN CLEAN THE AIR 
FILTER.  
AFTER CLEANING THE 
AIR FILTER,   
RESET THE FILTER 
TIMER 
A note of precaution when cleaning the air filter. 
Please immediately turn the power OFF, and clean or 
change the air filter by referring to the “Air Filter” 
section of this manual. After you have cleaned or 
changed the air filter, please be sure to reset the filter 
timer. (
39) 
 
NOTE  • A lamp has a finite product life. Lamps are characterized by the fact 
that, after long hours of usage, a lamp will no longer light up, or the lamp will 
break or burst, etc.