Sony VPL-CX86 사용자 설명서

다운로드
페이지 46
22
VPL-CX75/CX76/CX85/CX86/FX51/FX52/FX52L/PX35/PX40/PX41
<Table 1>
<Table 2>
Item Number
Data
Remarks
Item
Upper byte
Lower byte
Data
Upper byte
Lower byte
STANBY
00h
00h
Get only
START UP
00h
01h
STARTUP LAMP
00h
02h
POWER ON
00h
03h
STATUS POWER
01h
02h
COOLING1
00h
04h
COOLING2
00h
05h
SAVING COOLING1
00h
06h
SAVING COOLING2
00h
07h
SAVING STABY
00h
08h
CONTROL MODE SEL
01h
05h
USER
00h
00h
SERVICE
00h
01h
LAMP TIMER
01h
13h
USE TIME
0000h-ffffh
*1
ROM VERSION
01h
1Dh
MAIN ROM VERSION
*2
SC ROM VERSION
01h
1Eh
SC ROM VERSION
*2
Channel Memory Reset
01h
Set only
Status Memory Reset
02h
Set Memory Reset
03h
03h
00h
00h
W/B All Save
04h
W/B Low Save
05h
W/B High Save
06h
Sircs (15bit category)
17h
Refer to table 4
_
00h
00h
Set only
*3
Sircs (20bit category)
19h
Refer to table 5
_
00h
00h
*1Example) In case the lamp timer indicates 1000H, return values are [03h] upper byte and [E8h] lower byte.
*2Example) In case the software version is 1.03, return values are [01h] upper byte and [03h] lower byte.
*3It is corresponded to single command only.
<Table 3>
Item Number
Data
 Item
Data
Upper byte
Lower byte
ACK
_
00h
00h
Undefined Command
01h
Size Error
04h
Select Error
01h
05h
Range Over
06h
NAK
Not Applicable
0Ah
Check Sum Error
10h
Framing Error
20h
Parity Error
F0h
30h
Over Rub Error
40h
Other Comm Error
50h
(VPL-FX51)
(VPL-FX51)
Approximate Return Waiting Times
The await-return time is approx. 50 msec.
n
This is the case, unless the communications are interfered anyway.