2.2.7 Status Commands 
DLE EOT n 
CT-S280 
CT-S300 
CT-S2000
CT-S4000
BD2-2220 
CT-S310 
support model 
PMU2XXX 
     
 
 
 
 
 
 
 
 
[See Also]
 
[Caution]
 
• Each status represents the current status. It is 1 byte data.
 
[Outline]
 
[The specification which is common to the model]
 
[Range] 
1≦n≦4 
[Code] 
<
10>H<04>H<n> 
[Function]  
Sending status in real-time
 
• If another data string of <10>H<04>H<n> (1 n 4) is received, the printer acts the same way as 
with this command. Therefore, the user should be reminded of this fact. 
• This command can be executed even if printer setting by ESC = is invalid.
 
• If ASB (Automatic Status Back) is enabled by GS a, it is necessary to discriminate between the 
status due to ASB and the status due to this command
 
• With parallel interface specifications, this command cannot be executed while the printer is in Busy 
state. 
• With serial interface specifications, this command is executed in offline state, receiving buffer full 
state, and error state.
 
• This command is dealt with when it is received.
 
• This command is executed even if the printer is in offline state, receive-buffer full state, or error 
state.
 
• The status is transferred without checking whether the host is ready to receive or busy.
 
Sends in real-time the status specified by “n”. 
• The DLE EOT n command cannot be interleaved into the code string of another command 
consisting of 2 bytes or more. 
 
n Status 
1 Printer 
status 
Status caused by an offline condition 
Status caused by an error 
Continuous paper detector status 
When memory SW1-3 is ON, the printer does not enter Busy state in the offline state and error 
state.
 
Suppose a command “ESC * m nL nH [d1 ... dk]”, where d1 = <10>H, d2 = <04>H, d3 = <01>H. 
[Example 1] 
 
If the printer sends DLE EOT 3 after the host has sent up to ESC 3 in its attempt to send ESC 3 n, 
the printer handles the ESC 3 as ESC 3 <10>H. Thus, the user should be cautious.
 