Epson 7000 사용자 설명서
![Epson](https://files.manualsbrain.com/attachments/a47e008ef11c984ab8b71f0fc83873b5a963bd98/common/fit/150/50/31cec7b3b2e304c684d8acb1063f7a8423171db6df8832d86330b0432118/brand_logo.png)
EPSON Stylus Pro 7000
Revision B
Disassembly & Assembly
Disassembly Flow
124
3.
Remove the two screws (CP(W) M3x8) securing the Type-B Option Slot
Cover, and remove the cover. Then remove seven screws (CP(W) M3x6)
securing the Main board and remove the board.
Cover, and remove the cover. Then remove seven screws (CP(W) M3x6)
securing the Main board and remove the board.
Figure 4-27. C299MAIN Board Removal
4.2.2.3 AC Inlet Removal
1.
Remove the Rear Cover as described in “Rear Cover Removal” on
page 118.
page 118.
2.
Remove the connector from CN001 on the PS board.
3.
Remove one white screw (CUPS:M4x8) securing the AC inlet, the AC inlet
ground cable, and the toothed washer (M4).
ground cable, and the toothed washer (M4).
4.2.2.4 Disassembly of the AC inlet
1.
Remove the holder from the printer as described in “AC Inlet Removal”
on page 124.
on page 124.
2.
Remove two white screws (Dish:M3x6) securing the AC inlet and remove
the inlet.
the inlet.
Figure 4-28. AC Inlet Removal
C A U T I O N
When removing/re-inserting the flat-cable (FFC) from/to a
connector, make sure to pull/insert the cable straight.
Otherwise, internal contact of the connector may be damaged
and this causes a short-circuit to destroy the electrical
circuitries.
connector, make sure to pull/insert the cable straight.
Otherwise, internal contact of the connector may be damaged
and this causes a short-circuit to destroy the electrical
circuitries.
A D J U S T M E N T
R E Q U I R E D
After replacing the main board, various adjustments are
required. For details about these adjustments, refer to Chapter
5, Adjustment.
required. For details about these adjustments, refer to Chapter
5, Adjustment.
Two I/F
screws
Two
screws
Three screws
Two
screws
When replacing the AC inlet, make sure the label faces up.
AC inlet
Two
screws