Epson 7000 사용자 설명서

다운로드
페이지 231
EPSON Stylus Pro 7000
Revision B
Product Description
Interfaces
23
1.2.1  Parallel Interface - Compatibility Mode
The BUSY signal is set high before setting the -ERROR signal low or the PE 
signal high. The BUSY signal remains high until all these signals return to 
their normal, inactive state.
The BUSY signal is high:
„
When receiving data
„
When the input data buffer is full
„
When the -INIT signal is low, or during hardware initialization
„
During a printer error
„
When the parallel interface is not selected
The ERROR signal is low when there is a:
„
Printer hardware error (fatal error)
„
Paper-out error
„
Paper-jam error
„
Ink-out error
NOTE: The PE signal is high during paper-out errors.
DATA TRANSMISSION TIMING
Figure 1-3.  Data Transmission Timing
Table 1-13.  Parallel Interface Specifications
Item
Description
Transmission mode
8-bit parallel, IEEE-1284 compatibility mode
Synchronization
By STROBE pulse
Handshaking
By BUSY and ACKNLG signal
Logic Level
TTL compatible level (IEEE-1284 Level 1 device)
Connector
57-30360 (Amphenol) or equivalent
Note: Use a twisted-pair cable that is as short as possible.
DATA
data byte n
data byte n + 1
-STROBE
BUSY
-ACKNLG
t
hold
t
setup
t
stb
t
ready
t
busy
t
reply
t
ack
t
nbusy
t
next