3.3  Errors That Require a Service Technician
MAINTENANCE CALL 0100
†
Problem
The waste ink pads are almost full, causing a warning error. The 
printer can continue printing, but this messages overrides status 
messages such as Ready or Printing.
†
Solution
Replace the following parts and reset the counters as described below
„
Waste Ink Pads
„
F Box
„
Pump Assembly
„
Cap Assembly
„
Cleaner, Head
„
From Maintenance Mode 2 enter the Counter Init. Menu and initialize 
the Waste Ink counter and Cleaning counter.
SERVICE CALL 00000100
†
Problem
The waste ink pads are completely full, causing a fatal error. The 
printer stops printing.
†
Solution
Replace the following parts and reset the counters as described below
„
Waste Ink Pads
„
F Box
„
Pump Assembly
„
Cap Assembly
„
Cleaner, Head
„
From Maintenance Mode 2 enter the Counter Init. Menu and initialize 
the Waste Ink counter and Cleaning counter.
SERVICE CALL 00000101
†
Problem
A printer part has exceeded its useful life, and to prevent damage to 
other parts as well as abnormal operations/printouts, an error occurs. 
This error occurs when the CR Motor has reached 2.5 million passes, 
and this indicates the ink tubes should be replaced due to excessive 
wear and tear.
†
Solution
To make sure the ink tubes are not worn out, verify no part of any of 
the tubes shows wear, is loose, or leaks ink anywhere, especially the 
tube area between the printheads and the ink pipes.
SERVICE CALL 00010000
†
Problem
PF motor encoder check error
The PF motor makes small revolutions clockwise and counter-
clockwise. When it turns, the printer checks the rotary encoder (inside 
the motor) output signals to make sure the motor is turning at the 
correct speed/distance. If the encoder sends an incorrect signal, an 
error occurs.
†
Solution
Make sure there is nothing blocking the grid rollers. If that does not 
solve the problem, check the PF motor encoder connection. If there 
still is a problem, try the following.
„
Check and adjust the PF Belt tension
„
Replace the PF motor
„
Replace the Main Board