Intermec PF4i 사용자 설명서

다운로드
페이지 162
132 
Intermec EasyCoder PF4i Compact Industrial—User’s Guide (Fingerprint)
Appendix C—Interfaces
RS-232 Interface
Protocol
Default setup: 
Baud rate: 
9600
Char. length 
8 bits
Parity:  
None
Stop bits: 
RTS/CTS Disabled
ENQ/ACK: Disabled
XON/XOFF: 
Disabled (both ways)
New Line: 
CR/LF
To change the RS-232 interface settings, see Chapter 6, “Setting Up the 
Printer.”
Signals on printer’s serial port "uart1:"
DB-9
Signal Meaning
1
External +5V DC*
2
TXD
Transmit data
3
RXD
Recieve data
4
DSR
Data set ready
5
GND
Ground
6
DTR
Data terminal ready
7
CTS
Clear to send
8
RTS
Request to send
9
Not used
*
/. The external +5V is limited to 500 mA and is automatically switched 
off at overload. 
Interface Cable
Computer end:  Depends on computer model 
Printer end:  
DB-9pin plug
RS-232
("uart1:")