IBM RS/6000 44P 사용자 설명서
Setting the Write-Protect Tab on 12/24 GB 4 mm Tape Cartridges
Set the write-protect tab on a tape cartridge so that you do not accidentally lose
information. The write-protect tab on the tape cartridge controls write-protection. When
the write-protect tab on a tape cartridge is closed, information can be read from the
tape and written to it. When the write-protect tab on a tape cartridge is open,
information can be read from the tape, but not written to it.
information. The write-protect tab on the tape cartridge controls write-protection. When
the write-protect tab on a tape cartridge is closed, information can be read from the
tape and written to it. When the write-protect tab on a tape cartridge is open,
information can be read from the tape, but not written to it.
1
Write-protect tab closed: Write enabled
2
Write-protect tab open: Write disabled
Erasing 12/24 GB 4 mm Data Cartridge
Most bulk eraser devices cannot erase 12/24 GB 4 mm data cartridges. To properly
erase an 12/24 GB 4 mm data cartridge with a bulk eraser device, the erasure rating
must be at least 3900 oersted.
erase an 12/24 GB 4 mm data cartridge with a bulk eraser device, the erasure rating
must be at least 3900 oersted.
Environmental Considerations for 12/24 GB 4 mm Data Cartridges
This section describes operating and storage conditions including temperature, relative
humidity, and maximum wet bulb data.
humidity, and maximum wet bulb data.
Attention: The manufacturer specifies a set of temperature and humidity ranges in
which the 12/24 GB 4 mm data cartridge can operate with ease. Only
regular cleaning procedures are required when operating the cartridge
within this range. The risk of possible data loss is increased if 12/24 GB 4
mm tape cartridges are operated, stored, or shipped outside the
temperature or humidity ranges shown in the following table.
regular cleaning procedures are required when operating the cartridge
within this range. The risk of possible data loss is increased if 12/24 GB 4
mm tape cartridges are operated, stored, or shipped outside the
temperature or humidity ranges shown in the following table.
Condition
Operating Ranges
Storage
Shipping
Temperature
60°F-90°F (16°C-32°C)
41°F-90°F (5°C-32°C)
-40°F-126°F
(-40°C-52°C)
Relative Humidity
(non-condensing)
(non-condensing)
20%-80%
20%-80%
20%-80%
Maximum Wet Bulb
79°F (26°C)
79°F (26°C)
79°F (26°C)
32