Functional test of the sensors From each of the 
laminators, upper and lower, remove the transfer 
guide and the laminate patch, if any, beneath it. The 
sensor should read high, around 
250
. Replace the 
guide, and the sensor should read no lower than 
180
. If 
lower than 180, move the sensor board away from the 
transfer rollers, to the left, diagram below. 
Complete the test by running laminate onto the rollers 
(press the LAMINATE button). The sensor should 
read below 20. Adjust sensor board to correct.
Laminate Station Adjust 
Start
 > Printers (or Printers and Faxes) > Right click 
Zebra P640i > Properties > Device Settings > Printer 
Adjustment >
 Laminate Station Adjust 
Length Adjust (mils): This is the length of the 
laminate “patch”. If the patch is too long, decrease this 
number, and vice versa. 
Horizontal Offset (mils): Adjusts laminate 
placement on the card. 
Heater Temperature : This is the set point - 
temperature desired - not the actual temperature. For 
actuals, see Sensor Data, preceding page. NOTE: 
Temperatures are monitored by thermocouples at the 
core
 of the heated rollers. Surface temperatures may 
differ significantly. 
Line Voltage: If Auto is selected, the printer guesses 
line voltage based on line frequency, assuming that 
110V will be @ 60Hz, and 230V @ 50Hz. If this isn’t 
the case in your locality, the printer will guess wrong, 
and you should set the voltage manually. 
This setting has nothing to do with the printer power 
supply. Like the laminator heaters, the power supply 
can handle any voltage from 110V to 230V, so an 
incorrect setting here will cause no immediatedamage. 
Correcting Laminator Problems
Problem
 
Laminate bunches up outside the cutter assembly, 
having missed the feed slot. This can happen to either 
upper or lower laminates. It is probably a cassette 
installation problem, such as: 
1. Failing to latch the cassette
2. Out-of-square scissor cut on the leading edge of the 
laminate
3. Leading edge of laminate not reeled in even with 
the lips of the cassette.  Reference Section 2, Media 
Handling. 
Caution • The sensor board must be 
symmetrically positioned relative to the 
transfer rollers. with its attachement 
screws central in their slots. 
Caution • 
Do not set the temperature ABOVE 
180°C, or BELOW room temperature
Note • 
Running the printer at 220V, 
60Hz in Auto mode may cause premature 
failure ofthe heaters. Running the printer 
at 110V, 50Hz in Auto mode may cause 
abnormally long heat-up time and poor 
temperature control. 
 It is possible to 
get a false 
“good” reading 
if the sensors 
are too close to 
the feed rollers.