FEED Key and PAUSE Key
Press and hold these two keys while turning the printer power ON. The printer configuration will be
temporarily reset to the factory default values. These values will be active until power is turned OFF.
If the factory default values are permanently saved, a media calibration procedure must be
performed. You must also reset the head resistance value, and the verifier and applicator port
settings to their required values (see “Configuration and Calibration”).
The following chart indicates which printer function controls each of the configuration parameters:
Parameter
Controlled by
Darkness
Configuration and ZPL
Tear Off
Configuration and ZPL
Print Mode
Configuration and ZPL
Media Type
Calibration, Configuration, and ZPL
Sensor Type
Configuration and ZPL
Print Method
Calibration, Configuration, and ZPL
Print Width
Configuration and ZPL
Label Length
Calibration, Configuration, and ZPL
Maximum Length
Configuration and Memory Size
Host Port
Configuration
Baud
Configuration
Data Bits
Configuration
Parity
Configuration
Stop Bits
Configuration
Host Handshake
Configuration
Protocol
Configuration
Network ID
Configuration and ZPL
Communications
Configuration and ZPL
Control Prefix
Configuration and ZPL
Format Prefix
Configuration and ZPL
Delimiter Character
Configuration and ZPL
ZPL Mode
Configuration and ZPL
Ribbon Tension
Configuration and ZPL
Media Power Up
Configuration and ZPL
Head Close
Configuration and ZPL
Backfeed
Configuration and ZPL
Label Top
Configuration and ZPL
Left Position
Configuration and ZPL
Head Test Count
Configuration and ZPL
Head Resistance
Configuration (must match head resistance label value) or ZPL
Verifier Port
Configuration and ZPL
Applicator Port
Configuration and ZPL
Start Print Signal
Configuration and ZPL
Resynch Mode
Configuration and ZPL
Ribbon Low Mode
Configuration and ZPL
Reprint Mode
Configuration and ZPL
Web Sensor
Configuration and ZPL
Media Sensor
Configuration and ZPL
Ribbon Sensor
Configuration and ZPL
Mark Sensor
Configuration and ZPL
Mark Media Sensor
Configuration and ZPL
Media LED
Configuration and ZPL
Ribbon LED
Configuration and ZPL
Mark LED
Configuration and ZPL
Troubleshooting