Lenovo 9352 사용자 설명서
Diagnostic Error Code
FRU/Action
001-024-XXX
System Addressing test failure
System Addressing test failure
System board
001-025-XXX
System Checksum Value error
System Checksum Value error
1.
Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
(flashing) BIOS from a CD-ROM or
diskette” on page 786
2.
System board
001-026-XXX
System FLASH data error
System FLASH data error
1.
Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
(flashing) BIOS from a CD-ROM or
diskette” on page 786
2.
System board
001-027-XXX
System Configuration/Setup error
System Configuration/Setup error
1.
Run Setup
2.
Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
(flashing) BIOS from a CD-ROM or
diskette” on page 786
3.
System board
001-032-XXX
System Device Controller failure
System Device Controller failure
System board
001-034-XXX
System Device Buffer Allocation failure
System Device Buffer Allocation failure
1.
Reboot the system
2.
Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
(flashing) BIOS from a CD-ROM or
diskette” on page 786
3.
Run memory test
4.
System board
001-035-XXX
System Device Reset condition detected
System Device Reset condition detected
System board
001-036-XXX
System Register error
System Register error
System board
001-038-XXX
System Extension failure
System Extension failure
1.
Adapter card
2.
System board
001-039-XXX
System DMI data structure error
System DMI data structure error
1.
Flash the system. See “Updating
(flashing) BIOS from a CD-ROM or
diskette” on page 786
(flashing) BIOS from a CD-ROM or
diskette” on page 786
2.
System board
001-040-XXX
System IRQ failure
System IRQ failure
1.
Power-off/on system and re-test
2.
System board
001-041-XXX
System DMA failure
System DMA failure
1.
Power-off/on system and re-test
2.
System board
001-195-XXX
System Test aborted by user
System Test aborted by user
Information only
Re-start the test, if necessary
Re-start the test, if necessary
001-196-XXX
System test halt, error threshold exceeded
System test halt, error threshold exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
58
Hardware Maintenance Manual