Siemens PCIL43 사용자 설명서

다운로드
페이지 112
Commissioning 
 
7.3 Notes on operation 
 
SIMATIC Rack PC IL 43 
7-4
 
Operating Instructions, Edition 09/2005, A5E00432875-01 
7.3.3 
Removable hard disks 
The removable disk racks can also be hot swapped in connection to RAID1. 
Replacing a hard disk 
 
 
Caution 
Hard drives may only be swapped out of the removable frames when the disks are inactive 
and the device status displays are off. 
How to remove the hard disk drive: 
1.  Establish which hard disk drive of the RAID controller was reported as faulty (hard disk 
drive to channel 1 or 2). 
 
(1) 
Power LED 
voltage supply available 
 
 
(2) 
HDD activity display 
This display is always off. Please 
note the activity display HARDDISK 
(3) on the front of the device. 
The following table details the layout of the removable frames in the device according to the 
RAID system reports: 
 
RAID BIOS 
RAID Software 
SATA interface 
Installation location 
Port 0 
Device Port 0 
SATA1 
(4) Removable frame 1 
Port 2 
Device Port 2 
SATA3 
(5) Removable frame 2 
You will find information regarding the reconfiguration of the RAID association in the next 
section. 
1.  Set the key switch to the "OPEN" position. 
2.  Push up the bezel of the hard disk cartridge. 
3.  Remove the hard disk cartridge. 
Notes on operation 
 
 
Notice 
To ensure reliable operation of the devices in a removable disk rack, you need to interlock 
the hard disk cartridge with the disk rack.