Troubleshooting  
12.2 Problems when using modules of third-party manufacturers 
 
SIMATIC Rack PC IL 43 
12-2
 
Operating Instructions, Edition 09/2005, A5E00432875-01 
Problem  
Possible cause 
To correct or avoid error 
The USB ports are disabled 
in your BIOS. 
Use a different USB port or enable the port. 
USB 2.0 device connected 
but USB 2.0 is disabled. 
Enable USB 2.0. 
USB device not responding. 
Operating system does not 
support the USB port. 
Enable USB Legacy Support for the mouse and keyboard. 
For all other devices you need USB drivers for the specific 
operating system. 
DVD/CD: The front loader 
does not open. 
The device is switched off 
or the open/close button is 
disabled by a software 
application. 
Emergency removal of the data medium: 
1.  Switch off the device 
2.  Insert a pointed object, a pin for example, or an opened 
paper clip into the emergency extraction opening of the 
drive. Apply slight pressure to the contact until the front 
loader opens. 
3.  Pull the loader further out. 
The RAID software reports 
the following error: 
• 
The RAID plug-in failed 
to load, because the 
drive is not installed. 
• 
The Serial ATA plug-in 
failed to load, because 
the driver is not installed 
correctly. 
• 
The Intel® Matrix 
Storage Console was 
unable to load a page 
for the following reason: 
– 
A plug-in did not 
provide a page for 
the selected device 
– 
A plug-in failed to 
load 
RAID is not activated 
 
RAID is activated 
In this case, the reports have no negative influence on device 
function and can be ignored. Please acknowledge the reports. 
In this case, please re-install the software from the supplied 
Documentation and Drivers CD. 
12.2 
12.2 
Problems when using modules of third-party manufacturers 
 
Problem 
Possible cause 
To correct or avoid error 
Check your computer configuration: 
• 
If the computer configuration corresponds with factory state, 
please contact your technical support team. 
• 
If the computer configuration has changed, restore the 
original factory settings. Remove all third-party modules, 
then restart the PC. If the error no longer occurs, the third-
party module was the cause of the fault. Replace this 
module with a Siemens module or contact the module 
supplier. 
• 
Force a “Reset Configuration” using the BIOS setup. 
The PC crashes 
during startup 
• 
I/O addresses are assigned 
twice. 
• 
Hardware interrupts and/or 
DMA channels are assigned 
twice. 
• 
Signal frequencies or signal 
levels are incorrect. 
• 
Connector assignments 
deviate. 
• 
“Reset Configuration” in BIOS 
SETUP has not been carried 
out. 
If the PC still crashes, contact your technical support team.