Troubleshooting
ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B)
104
To solve the problem, proceed as follows:
1. Make sure that all DIMMs of correct type are installed in the slots properly.
2. Check for consistency of the size and frequency of the installed DIMMs.
3. Re-install the DIMMs.
For details, see 
.
4. Replace the DIMM.
For details, see 
.
5. If the problem persists, replace the ATCA-7150.
For details, see 
A.9
Power Exceptions
A.9.1
ATCA-7150 Cannot Be Started
Description
The ATCA-7150 cannot be started.
Solution
To solve the problem, proceed as follows:
1. Make sure that the shelf is powered on properly.
For details, refer to the respective system documentation.
2. If you install an optional component on the ATCA-7150, remove the optional component 
and then restart the ATCA-7150.
3. Start another ATCA-7150 in the shelf. If it can be started normally, replace the faulty ATCA-
7150.
4. If the problem persists, see