Emerson RTM-ATCA-7150 사용자 설명서

다운로드
페이지 122
   
Hardware Installation of ATCA-7150
ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B)
72
3.3.2
Power Requirements
Make sure that the blade is used in an AdvancedTCA shelf connected to -48VDC up to -60VDC, 
according to Telecommunication Network Voltage (TNV-2). A TNV-2 circuit is a circuit whose 
normal operating voltages exceed the limits for a safety-extra-low-voltage (SELV) under 
normal operating conditions, and which is not subject to overvoltages from 
telecommunication networks.
 lists the power requirements for the ATCA-7150.
The blade provides two independent power inputs according to the AdvancedTCA 
specification.
Free Fall
1,200 mm (Packaged) /all 
edges and corners 
1.0m (Packaged) per ETSI 
300 019-2-2 (Blade level 
packaging)
25 mm (unpackaged) per 
GR-63-CORE
Table 3-2 Environmental Requirements (continued)
Requirement
Operating
Non-Operating
Table 3-3 Power Requirements
Requirement
Operating
Rated Voltage
-48VDC to -60VDC
US and Canada: -48VDC
Operating Voltage
-39.0VDC to -72VDC
US and Canada: -39.0 to -60VDC
Input Current
3.75A at 48V
Power Dissipation
180W (max) 140W (min)