Emerson ATCA-S201 사용자 설명서

다운로드
페이지 157
RTM-ATCA-SXXX Overview 
6806800H62B 
ATCA‐S201 Installation and Use Guide 
 
102 
AMC slot B1
AMC slot B2
AMC slot B3
AMC slot B4
DDR2 DIMM
J23
J10
CPU
PCIe
Switch
SAS
10GbE
XAUI
ATCA-S201
JP1
JP2
J30
J32
J33
3   2   1
3   2   1   
 
Figure 30 ATCA-S201 Jumper locations 
 
 
9.4.2  Emergency flash recovery (factory reset) 
The method described in this section explains a procedure to repair primary flash 
contents that are blank, erased or corrupted.  We advise against using this 
emergency recovery procedure if the ATCA-S201 is functional, and management 
communications can be conducted.   
 
Upgrade firmware procedure  
1.  Remove the ATCA carrier the chassis (see 2.9, Removing the ATCA carrier 
2.  Locate header JP1, and move the jumper to the service setting.  This causes the 
blade to fetch firmware from the read-only factory flash. 
3.  Re-install the ATCA blade into the chassis and allow it to reboot.