RTM-ATCA-SXXX Mechanical and Connector Information 
6806800H62B ATCA-S201ATCA-S201 Installation and Use Guide 
130 
Table 60 Environmental Specifications for the ATCA-S201 
SPECIFICATION 
VALUE 
Operating Temperature (airflow 3.1 CFM) 
0°C ~ 55 °C  
Storage Temperature 
-40 °C ~ 85 °C 
Operating Temperature Gradient 
11 °C /H (max) 
Storage Temperature Gradient 
20 °C /H (max) 
Shipping Temperature Gradient 
20 °C /H (max) 
*1
 
Operating Humidity 
8 % ~ 80 % 
Storage Humidity 
5 % ~ 95 % 
Shipping Humidity 
5 % ~ 95 % 
*1
 
Wet bulb Maximum Temperature 
27 °C 
Condensation No 
condensation 
Atmospheric Pressure and Altitude 
Operating: 0 ~ 3,000 m 
Shipping: 0 ~ 12,000 m 
Operating Shock  
 
See PICMG 3.0 specification, Regulatory 
guidelines. 
Operating Vibration 
See PICMG 3.0 specification, Regulatory 
guidelines. 
RoHS 
6 of 6 compliant. 
13.1.4  NEBS Compliance 
NEBS certifications are performed by integrator at a system level (chassis, ATCA, 
AMC shelf managers etc). The RTM module will not preclude the system form 
passing NEBS.   
13.1.5  Electromagnetic Compliance   
The board is designed and implemented so as to minimize electromagnetic 
emissions, susceptibility, and the effects of electrostatic discharge.  The board 