ATCA‐S201 Installation 
 
 
6806800H62B 
ATCA‐S201 Installation and Use Guide 
 
19 
2.10.1  To Verify the Hardware Installation 
1.  After power is applied to the system, wait approximately 45 seconds for 
firmware to initialize the board.    
2.  Inspect the LEDs on the front of the ATCA panel.  When properly installed and 
powered,  the  LEDs will illuminate as  follows:  
  ATCA Hot Swap LED 
 
Off: Normal, default state  
  ATCA Health status 
 
Green-blinking: Healthy, OK 
  ATCA Out of service (OOS) 
Off: Normal, default state  
3.   (Optional).  There are five Ethernet ports on the ATCA blade: 
  1 management (on RTM) 
  2 ATCA base ports (zone-2 connector) 
  2 ATCA fabric ports (zone-2 connector) 
If DHCP is running on the network, it is possible to immediately ping the 
Ethernet ports on the ATCA module.  Open a command line window on any 
node, and attempt to ping the ATCA blade.    
 
ok ping 192.168.1.xxx 
Note1: Ping requires that you determine the IP address assigned to the blade.  The 
carrier blades MAC address assignments are registered with the IANA public section 
of the IEEE Standards OUI (Organizational unique identifier) database.  The Ethernet 
ports for the blade can be identified by finding the IP address corresponding to the 
following MAC address assignments: 
 
MAC address OUI 
00-11-0D-xx-xx-xx   (hex)