14
®
®
Features | Front Panel
21.   Battery Run Time Stage – during a power outage, this unit will 
shut down power to your connected home theater equipment in 
stages (unless override is on). Each stage is associated with specific 
rear-panel power outlets. This display indicates which stage(s)  
have shut down, which stage the unit is currently in, and which 
stage(s) remain.  
 
An empty circle (e.g., 
ö
): 
stage already shut down
 
A blinking circle: 
 
current stage
 
A solid circle: 
 
future stage
 
 During battery backup or normal operation, you can press the 
“Stage Time” button to cycle through each stage and see how much 
usable battery-backup time each stage has. Note, however, if the 
override feature is on, there are no shutdown stages so only the 
override battery-backup time can be viewed (i.e., estimated total 
battery-backup time without any automated stage shutdown).
22.  Battery-Backup Time – during normal operation or battery backup, 
these numbers automatically update to show you how much 
approximate battery-backup time there is for any specific stage (or 
total battery-backup time if staged shutdown is overridden).
23.  Battery ON – this will only display when the unit’s battery is being 
used (e.g., during a power outage).
24.  Battery OK – this will remain displayed so long as the unit’s battery 
is in good health.
25.  Overload – when the battery’s load level approaches a critical level, 
the overload icon will appear (it will blink on and off).  
This may happen if your connected equipment is drawing/
consuming too much power. If the battery load exceeds its 
maximum safe threshold, the entire unit will automatically shut 
down to prevent damage.
26.  Replace Battery – this will display when the unit’s battery is in 
poor health and must be replaced. If a power outage occurs when 
the battery needs replacing, the AVU1500 will simply shut down 
immediately. See “Battery Replacement” on page 45 for  
more details.
27.   Battery-load meter – this meter illustrates the size of the load (in 
watts) currently placed on the AVU1500. During normal operation, 
with no connected equipment, the load meter will register a 
minimal load (one bar). As equipment is added, the load meter will 
increase. The maximum load that the AVU1500 can safely handle is 
1000 watts and all five of the meter’s bars will blink when the unit 
exceeds a safe maximum capacity.    
28.  Battery-charge meter – shows the battery’s charge level (i.e., 
the remaining usable battery power supply). If the battery is 
fully charged, then all five bars will be displayed. If the battery is 
charging, the bars will blink on and off (similar to a mobile phone).