Furuno M51A 사용자 설명서

다운로드
페이지 22
DLM 600W Series  
Isolated Remote Analog Interface Operation 
M51A Option 
2-5 
2.3.1 
ISOLATED ANALOG INTERFACE Functions 
 
The following sections describe the functions of the various signals of the ISOLATED ANALOG 
INTERFACE.  Pin numbers correspond to the connector pinout of Table 2–2. 
 
Digital Control Input Signals 
 
ANALOG-CONTROL: 
Pin-1, enables remote analog programming with an active-high logic 
level of 3-15VDC.  An internal 100kΩ pull-down resistor is provided.  When ANALOG-
CONTROL is asserted, the power supply will power-up with the analog interface in control of the 
output voltage.  Signal is referenced to Pin-6.  Circuit is SELV, and has electrical isolation from 
the output of the unit. 
EXTERNAL-OFF:  Pin-14, disables the output when asserted.  Active logic level could be 
selected with the INTFC SETUP switch to be high (3-30VDC) or low.  An internal 100kΩ pull-
down resistor is provided.  Signal is referenced to Pin-2.  Circuit is SELV, and has electrical 
isolation from the output of the unit. 
Digital Control Output Signals 
 
VOLTAGE-MODE: 
Pin-5, nominal 5VDC logic level indicates operation in constant-voltage 
mode.  Source resistance is 2kΩ.  Signal is referenced to Pin-6.  Circuit is SELV, and has 
electrical isolation from the output of the unit.   
OVP: Pin-17, nominal 5VDC logic level indicates that the output has been disabled because of 
overvoltage protection. Source resistance is 2kΩ.  Signal is referenced to Pin-6.  Circuit is 
SELV, and has electrical isolation from the output of the unit.   
 FAULT: Pin-18, nominal 5VDC logic level indicates that the output is disabled because of 
overtemperature or summary fault. Source resistance is 2kΩ.  Signal is referenced to Pin-6.  
Circuit is SELV, and has electrical isolation from the output of the unit.   
 
Analog Monitor Signals 
 
VOLTAGE MONITOR, 0-5/10V: 
Pin-19, readback of the output voltage is provided with a 
0-5VDC or 0-10VDC signal (user selectable with INTFC SETUP switch) indicating  
0-100% of full scale output.  Signal is referenced to Pin-2.  Circuit is SELV, and has electrical 
isolation from the output of the unit.  
VOLTAGE MONITOR, 4-20mA: Pin-4, readback of the output voltage is provided with a 
4-20mA signal indicating 0-100% of full scale output. Signal return for the 4-20mA current is 
Pin-6.  Circuit is SELV, and has electrical isolation from the output of the unit.  
CURRENT MONITOR, 0-5/10V:  Pin-7, readback of the output current is provided with a 
0-5VDC or 0-10VDC signal (user selectable with INTFC SETUP switch) indicating  
0-100% of full scale output.  Signal is referenced to Pin-2.  Circuit is SELV, and has electrical 
isolation from the output of the unit.  
CURRENT MONITOR, 4-20mA: Pin-24, readback of the output current is provided with a 
4-20mA signal indicating 0-100% of full scale output. Signal return for the 4-20mA current is 
Pin-6.  Circuit is SELV, and has electrical isolation from the output of the unit.