Furuno M51A 사용자 설명서

다운로드
페이지 22
DLM 600W Series  
Isolated Remote Analog Interface Operation 
M51A Option 
2-9 
4. 
Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING 
INPUT, Pin-9, and the CURRENT PROGRAMMING INPUT, Pin-10, with respect to 
Pin-12. 
 
5. 
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE 
connector to Pin-15. 
 
2.4.4 
2.4.5 
Resistance 
Programming of Output Voltage 
 
Setting up for resistance programming of the output voltage is as follows: 
 
1. 
Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming 
range. 
 
2. 
Connect the external programming resistance, 0-5kΩ,  to the ISOLATED ANALOG 
INTERFACE connector, from Pin-21 to Pin-12. 
 
3. 
Connect a jumper from Pin-21 to Pin-9. 
 
4. 
Program the other parameters to the desired limit values: CURRENT PROGRAMMING 
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to Pin-12. 
 
5. 
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE 
connector to Pin-15. 
 
Resistance 
Programming of Output Current 
 
Setting up for resistance programming of the output current is as follows: 
 
1. 
Set Position-2, I, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming 
range. 
 
2. 
Connect the external programming resistance, 0-5kΩ,  to the ISOLATED ANALOG 
INTERFACE connector, from Pin-22 to Pin-12. 
 
3. 
Connect a jumper from Pin-22 to Pin-10. 
 
4. 
Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING 
INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3, with respect to Pin-12. 
5. 
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE 
connector to Pin-15.