Power Protection UPS
 RU103                                                                                                                   User Manual 
 
 
7.
  USB Communication Port 
The built-in USB port connects to your computer. The PowerGuard Smart   
monitoring and shutdown software provided can automatically save your files 
and shut down your computer in the event of a prolonged power outage. The   
software also provides information regarding the status of your utility power 
line
   
Installing software 
 
 
 
 
 
If autoplay is not enabled on the computer, please follow instructions below: 
‧Double-click on My Computer on the desktop. 
‧Double-click on the CD-ROM drive icon and follow the on-screen 
instructions.
 
 
8.
  Data /Phone/Fax Protection Connectors 
 
9.
  “Surge Only” Outlets 
 
Four Nema 5-15R output receptacles that will provide surge and spike 
protection only
   
 
10.
 “Battery & Surge” Outlets 
Four Nema 5-15R output receptacles that will provide both battery backup and 
surge protection.
 
 
11.
 AC Input Power Cord 
Plug the AC power cord into your power source 
 
12.
 Coax in :   
TV/TNT/Satellite reception protection 
 
13.
 Circuit Breaker (re-
settable
The button will protrude when the overload condition occurs. If the button 
protrudes, disconnect some non-essential equipment and reset the circuit 
breaker by pushing the button inward.
 
 
 
14.
 Coax out: 
TV/TNT/Satellite reception protection 
 
INDICATOR TABLE 
Status Indicators
 
The UPS provides both visual and audible status indicators. Visual indicators consist 
of three LEDs to represent the following conditions:   
• 
On utility power operation 
• 
On battery power operation 
• 
UPS fault/alarm 
 
LED and Alarm Indicator Table 
UPS Status 
Green 
LED 
Red LED 
Yellow 
LED 
Alarm 
Self-test Blink 
B1 
Normal On 
Self Low 
battery 
On Blink2  X 
B5 
AC mode 
( on utility) 
overload On  Blink2 
B2 
Normal X 
On 
B1 
Low 
battery 
X X 
Blink2 B3 
DC mode 
( on battery) 
Overload X  Blink2  On 
B2 
Short/Fault mode 
On   
On 
Over-Bat/Bat Fault 
Blink2 
B4 
* Blink 1 : ON 0.5 seconds / OFF 1 seconds 
* Blink 2 : ON 0.25 seconds / OFF 0.25 seconds 
* B1: 1 beep / 5 seconds: ON 0.25 seconds / OFF 4.75 seconds 
* B2: 1 beep / 0.5 seconds :ON 0.25 seconds / OFF 0.25 seconds 
* B3 : 2 beeps / 5 seconds: ON 0.25 seconds / OFF 0.25 seconds 2 times, 4 seconds OFF 
* B4 :    3 beeps / 5 seconds: ON 0.25 seconds / OFF 0.25 seconds 3 times, 3.5 seconds OFF 
* B5: 3beeps / 30seconds :ON 0.25 seconds / OFF 0.25 seconds 3 times, 28.5seconds OFF
 
 
Recycling Information: 
Your UPS contains Non-Spill Sealed Lead Batteries. On the battery you will 
find the battery name. Please reference the chart below for recycling 
information. Other brand(s) of battery please contact Rosewill.com.   
Battery Name 
Recycling inside the USA 
Vision Battery 
1-877-730-2877 
First Power Battery 
1-877-730-2877 
BB Battery 
1-800-278-8599 
 
Follow the on-screen 
instructions
SPECIFICATIONS 
Model  
RU-103 
 
Capacity 
1500 VA / 900W 
Nominal Input Voltage 
120 Vac 
Nominal Output Voltage 
120 Vac 
Automatic Voltage 
Regulation (AVR) 
108-130Vac(±3%) 
Frequency 
50 / 60 Hz auto sensing 
8 Outlets (4 Battery Backup & Surge Protection; 
4 Surge Protection only) 
Outlets 
Lighting / Surge Protection
320 Joules 
Transfer time to Battery/AC
2-6ms typical 
Battery Type 
Maintenance free lead-acid battery 
(2)* 12V 9 Ah
 
Battery Specification 
Typical Backup Time 
4-7 Minutes 
RJ11/45 
LAN / Phone / Fax Protection
Short Circuit Protection 
Circuit Breaker 
Communication Port 
USB 
0°C–40°C 
Operation Temperature 
0 to 95% non-condensing 
Operation Relative Humidity 
Storage Temperature 
-15°C–50°C 
Net Weight 
29.3 lb 
Dimensions (HxWxD) 
10.8 x 3.4 x 16.1 IN 
Specifications may change without prior notice.                                                                                   
TROUBLESHOOTING 
Symptom 
Possible Cause
Action to Take 
Ensure the UPS is securely 
connected to an AC outlet. 
The UPS is not 
connected to the 
power source. 
UPS will not turn 
on 
Circuit Breaker has 
tripped. 
Reduce the amount of equipment 
plugged into the “Battery Backup & 
Surge Protection” outlets of the UPS.   
Reset the circuit breaker by pushing it 
back in. Switch the UPS back on. 
Turn off the UPS and reduce the 
amount of equipment connected to 
these outlets. 
The “Battery Backup & 
Surge Protection” 
outlets are overload. 
UPS is making a 
continuous 
sound and the 
“Overload” 
indicator is on 
The UPS battery is 
discharged due to a 
power outage and has 
not recharged. 
Charge the battery for 8 hours. The 
UPS runtime is reduced until the 
battery is fully charged. 
UPS does not 
provide 
expected 
runtime 
Back-UPS is heavily 
loaded. 
Unplug non-essential equipment 
(printers, scanners, etc) from the 
Battery Backup outlets and plug into 
'Surge Only' outlets 
Disconnect non-essential equipment 
from the UPS. Reset (push in) the 
circuit breaker and switch the UPS 
on. 
The UPS circuit 
breaker “tripped”. 
Plug equipment in one-at-a-time. If 
the circuit breaker trips again, 
disconnect the device that caused 
the breaker to trip. 
UPS does not 
power essential 
equipment 
during an outage 
Replace the battery or the battery 
module. 
The battery has 
reached the end of its 
life.  
Unplug device from 'Surge Only' 
outlet and move to a 'Battery Backup 
outlet. 
Equipment plugged 
into a Surge Only 
outlet. 
Flashing 
Indicators 
Internal UPS fault. 
Contact Technical Support (see 
Service and Support below). 
 
Thank you for purchasing a quality Rosewill Product. 
Please register your product at: www.rosewill.com for complete warranty information and future 
support for your product. 